Bang & Olufsen ML Gateway Installationsanleitung Seite 23

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 58
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 22
Programming 23
Devices - BeoLink
- Click on the tab Programming and then Devices.
- Click in the eld for BeoLink. The following resources
are now available:
BeoLink rooms
BeoLink products
Resources - BeoLink rooms / BeoLink products
The resources screen is where you identify all the necessary components with which ML Gateway will interact. The aim is to dene BeoLink rooms,
BeoLink products, events for the schedulers, and keypads or buttons for external systems.
Changes made to ML Gateway must be saved either by selecting the corresponding Apply button, or by pressing Enter.
For removing resources, select the Delete check marks before applying changes.
Auto setup of rooms and products
If there is a Beo5/6 project available in the customer setup, and it contains all rooms in whitch you need to receive LIGHT and CONTROL events, it
can be downloaded and automatically added to the list of rooms and products (if not, skip this step).
- Click on the Browse button and choose the Beo5/6 project le.
- Click Open.
- Click Load resources from Beo5 project le... (rooms and products will
automatically be appended to the current list).
BeoLink rooms
Rooms are needed for receiving LIGHT and CONTROL events from Beo4/Beo5. These
events are associated with rooms, where more than one product could possible receive
the same remote control command. The purpose of the table under the BeoLink rooms
section is to dene the rooms from which you need to receive light and control events,
and to dedicate a room number to each room.
- Name the desired rooms for programming in the table and give each one a specic
number (the sequence has no signicance).